II. CamassCrete CS1000A Super Low-Profile

40 mm / 50 mm / 60 mm height

 

Super-Low Cable Highway ------ Can only be built by Netfloor Systems

 

CS1000A-40 / CS1000A-50 / CS1000A-60 series
Cable Trench Capacity by different heights
Inside width: 110 mm (4.33")
Clearance: System height minus 5 mm

System

System height

Cable Trench width

Cable Trench clearance

CS1000A-40

40 mm (1.57")

110 mm (4.33")

35 mm (1.38")

CS1000A-50

50 mm (2.00")

110 mm (4.33")

45 mm (1.77")

CS1000A-60

60 mm (2.36")

110 mm (4.33")

55 mm (2.17")

Socket-Set-Crew fixed at top of the pedestal

 

Set-Screw Locking System --- for Super Low-Profile installation

 

Step 1:

 

Loose the lock-nut
Apply the 5 mm hex key wrench to loose the Set-Screw by counter-clockwise.

     

Step 2:

 

Adjust height  from top
Use the 4 mm hex key wrench, Stretch trough the Set-Screw, Insert at hex hole at top of the pedestal, then adjust height.

     

Step 3:

 

To fasten
After Step 2 height adjustment, apply the 5 mm hex key wrench to lock by clockwise.

 

5 mm
hex-key wrench

 

Step 1 and 3: to loose and lock Socket-Set-Screw from above

   

 

 

4 mm hex-key wrench

 

Step 2: to adjust height from top

 

CS1000A-40 to install at 40 mm high
35 mm clearance within Cable Trenches

 


Renovation jobs: Installing on the old, embed floor trunkings

 

Applications: to meet cable capacity and finish floor height requirements, both CS1000W and CS1000A systems are ideal for corporate headquarter, general office, school, library, public and private training institutes.

 

[ Prev ]    Page:   1    2    3    4    5    6    7    8    [ Next ]