Why Camass® is the right choice in office environment

Internet and intranet have been developing at an exponential speed. Access floors using in the office for cable management purposes becomes a necessity. The conventional raised access floors (CRF) that are used mainly for factory purposes have been lightly modified to be used in offices lately. Fundamentally, is not suitable for office environment. The chart below is a comparison made between the Camass® system and the CRF. The chart also serves to address some of the common issues.

"Camass" vs. "CRF"

 

Camass CA1000

Conventional
raised access floor

Panels

All steel

All steel or steel filled with cement

Flammability

Non-combustible

Non-combustible

Module set size

600 mm × 600 mm

600 mm × 600 mm

Weight

Avg. 24 kg / m2

24 kg / m2 (full steel)
or 36 kg ~ 40 kg / m
2

Cable Trenches

Total height

Clearance

Adaptability

40 mm 35 mm

Not suitable

Not suitable

76 mm 71 mm

Not suitable

Not suitable

100 mm

96 mm

100 mm & above

65 mm & above

Concentration load

300 kg < 2.5 mm
(1" square plate), full steel,
recovery at < 1mm

300 kg < 2mm
(1" square plate) steel/cement,
crack when > 2mm dep.

Cable management

Reticulated cable trenches 110 mm inside capacity every 600 mm

No Cable Trenches,
floor cable trunks are needed

Cable exit

Free extension from Cable Trenches

Difficult, panels need to be cut

Changeability

Pedestals non-glue to sub-floors, re-layout or relocation cause minor costs, least interference to normal office operation

Pedestals glued to sub-floors, re-layout or relocation more costly

Environment protection

100% recyclable
100% re-usable
Non-pollution to sub-floors

Avg. 20% recyclable
Avg. 80% re-usable
Pollution to sub-floors

User friendly

Trench caps can be easily lifted. UniPanel is self-standing, won't cause hazard

Need special tools. Time consuming. Heavy and loose panel are accident-prone

Cost of Relocation

"Low" easy relocation. Pedestals not glued. More than 90 % re-usable

"Costly" < 80 % re-usable. Pedestals glued and will damage sub-floor

Comfort on feet

"Acceptable" When installing carpet tile, tacky adhesives shall be applied to coverall surface of Camass

"Good" Walking on top of the steel/cement panel, will produce less noise than hollow welded panel.

Floor Condition for installation

Required better floor leveling condition. Need better floor condition, generally leveling needed

Generally leveling isn't necessary

Retrofit installation

Suitable to be installed at 76~40 mm (3" ~1.57") height

Not suitable installing under 100 mm (4") height

 

 